Results of the Interlaboratory Validation of EPA Method 1600 (mEI) for Enterococci in Wastewater Effluent

dc.creatorUnited States Environmental Protection Agency Office of Water
dc.date.accessioned2011-03-16T20:14:32Z
dc.date.available2011-03-16T20:14:32Z
dc.date.issued2004-02
dc.description53 pages; available for download at the link below.en
dc.description.abstractThis report presents the results of the U.S. Environmental Protection Agency's (EPA's) interlaboratory validation study (the "Study") of a membrane filtration procedure for the analysis of enterococcus in wastewater: EPA Method 1600 which uses membrane-enterococcus indoxyl(beta)-D-glucoside agar medium (mEI). The September 2002 version of the Method (EPA-821-R-02-022) was followed during the Study. The purposes of the Study were to characterize method performance (sensititivity, specificity, precision, and recovery) across multiple laboratories and disinfected wastewater matrices and to develop quantitative quality control (QC) acceptance criteria.en
dc.identifier.otherAccession # 11270
dc.identifier.urihttp://hdl.handle.net/1969.3/27792
dc.language.isoen_USen
dc.publisherUnited States Environmental Protection Agencyen
dc.relation.ispartofseriesEPA;821-R-04-008
dc.subjectwater quality analysisen
dc.subjectenterococcusen
dc.subjectwater qualityen
dc.subjectenvironmental protectionen
dc.titleResults of the Interlaboratory Validation of EPA Method 1600 (mEI) for Enterococci in Wastewater Effluenten
dc.typeTechnical Reporten

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
11270-Results of the Interlaboratory Validation of EPA Method 1600 (mEI) for Enterococci in Wastewater Effluent.pdf
Size:
2.07 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description: